Refrigerant 410a pressure

Typical Low Side Pressure Range for R410A in the field: 115-120 psi. Typical High Side Pressure Range for R410A in the field: 410-420 psi. By 2025, high Global Warming …

Refrigerant 410a pressure. Both older R-22 and R-134 operate at lower pressures than R-410A. R22 Refrigerant Pressure Rules of Thumb Typical Off, Low, High side R22 Pressures & Temperatures. On a properly-charged and working air conditioning system using R-22 refrigerant. Low pressure refrigerant switches on Carrier HVACR typically open at 50 psi and close at …

developments. Today, the air conditioning market is facing tough government pressure on energy savings and environment restrictions. R410A being a non-ozone depleting chemical able to improve energy e˝ciency, it is now proven that it will be the long-term replace-ment to HCFC refrigerants.

Conditions: 43.3 °C (110 °F) condenser/7.2 °C (45 °F) evaporator/2.8 °C (5 °F) of subcooling/8.3 °C (15 °F) of superheat. *Established by Occupational Alliance for Risk Science (OARS) Figure 1.. Pressure-Enthalpy Diagram for FreonTM 407C (ENG Units) Figure 2.. Pressure-Enthalpy Diagram for FreonTM 407C (SI Units) Figure 3.Under (Atmospheric) Pressure - The pressure of the atmosphere is immense, and it grows as you get closer to the planet's surface. Learn about pressure and how it affects weather. A...Alternative Refrigerants Evaluation Program (AREP) Compressor Calorimeter And System Drop In Tests With R-22 Alternatives By David S Godwin, Air-Conditioning & Refrigeration Institute (now AHRI) 18 March 1994 •AREP Results Led To Selection Of R134a, R404A, R407C & R410A In Various Applications •Higher Pressure Refrigerants Like R410A …What should my pressures be for 410A? Typically, for a properly charged R-410A system, the low-side (suction) pressure may range from 120 to 150 psi, and the …Freon™ 410A provides comparable performance to R-13B1 in most very low temperature, (VLT) applications. R-13B1 is an ozone-depleting refrigerant, and production has ceased as mandated by the Montreal Protocol and other legislation. Freon™ 410A offers similar performance to R-13B1 in existing systems, however, some equipment modificationsA. This Section includes refrigerant piping used for VRV/VRF air-conditioning applications. 1.2 PERFORMANCE REQUIREMENTS A. Line Test Pressure for Refrigerant R-410A: 1. Suction (low pressure gas) Lines: 550 psig, or per equipment manufacturers recommendation. 2.

Genetron® AZ-20 - (R-410A) Widely accepted to replace R-22 in air conditioning and refrigeration applications. For new equipment — not for retrofits. Overview. Specifications. Resources. Save this page as PDF. Widely accepted to replace R-22 in air conditioning and refrigeration applications. For new equipment — not for retrofits.Physical Properties Of R22. In parallel to using the R22 PT chart, professionals will usually need to know some of the following R22 physical properties: R22 liquid density at -69°C: 1.49 g/cm 3. R22 gas density at 15°C: 3.66 kg/m 3. Triple point temperature: -115.76K. Critical pressure: 49.36 bar. Heat capacity ratio at 86°F: 1.178253.410A Pressure: 410A operates at a higher pressure, leading to more efficient cooling cycles. However, this requires stronger, more robust components in the AC system. System Design Implications: Due to these pressure differences, AC systems specifically designed for one can only use the other with significant modifications.Watch this video to find out about the new GE Café Series refrigerator that has a Keurig drink dispenser built into the door to provide hot beverages. Expert Advice On Improving Yo...Freon ™ 410A Refrigerant (R-410A) 0 0 20 40 60 80 Temperature (°F) 100 120 140 R-22 R-410A 100 200 300 400 500 600 700 Product Information Freon™ 410A is a non-ozone depleting high efficiency hydrofluorocarbon (HFC) refrigerant. Freon™ 410A has higher cooling capacity and operating pressures than R-22 for new equipment specifically ...An R-22 Replacement for New ACs and Heat Pumps. Freon™ 410A (R-410A) refrigerant offers higher cooling capacity and significantly higher pressure than R-22 for use in … Freon™ 407C and Freon™ 410A Refrigerant Descriptions Freon™ 407C is a non-ozone depleting blend of three hydrofluorocarbon (HFC) refrigerants. It exhibits performance characteristics similar to R-22. Freon™ 410A is a non-ozone depleting blend of two HFC refrigerants. It exhibits higher pressures and refrigeration capacity than R-22.

Under Section 608 of the Clean Air Act, EPA prohibits individuals from knowingly venting refrigerants containing ozone-depleting refrigerants (including HCFC-22) as well as their substitutes (such as HFCs, including R-410A), while maintaining, servicing, repairing, or disposing of AC and refrigeration equipment. Report a potential … Refrigerant Pressure Temperature Chart - PT Chart for R-410A, R-134A, and R-22. These are currently the three most widely used refrigerants on the market today for HVAC applications in residential and commercial use. R-22 refrigerant is the king and used widely in the residential and commercial markets followed by R-134A which is used in ... Temp. Temp. Temp. Temp. Temp. Temp. Temp. Temp. ( F) Liquid Vapor ( C) ( F) Liquid Vapor ( C) ( F) Liquid Vapor ( C) ( F) Liquid Vapor ( C)-49 5.5 5.4 -45.0 1 49.7 49.5 -17.2 51 145.8 145.2 10.6 101 323.1 322.1 38.3-48 6.0 5.9 -44.4 2 51.1 50.8 -16.7 52 148.4 147.9 11.1 102 327.7 326.7 38.9Conditions: 43.3 °C (110 °F) condenser/7.2 °C (45 °F) evaporator/2.8 °C (5 °F) of subcooling/8.3 °C (15 °F) of superheat. *Established by Occupational Alliance for Risk Science (OARS) Figure 1.. Pressure-Enthalpy Diagram for FreonTM 407C (ENG Units) Figure 2.. Pressure-Enthalpy Diagram for FreonTM 407C (SI Units) Figure 3.

Dish barn hendersonville.

Forane. 427A (R427A) retrofit guidelines. Forane® 427A Refrigerant (R-427A) was commercialized in 2005 to supply the growing demand in Europe for an R-22 retrofit. R-427A has a similar capacity, efficiency, and mass-flow rate to R-22, making it an easy retrofit option for large, medium, and small air-conditioning and refrigeration systems.May 26, 2012 · Head pressure: 118F 83 + 35 = 118F more or less shows on the high side gauge if I understand this correctly. Low side pressure: 125 psi = 42 saturation temp. 66.2 low side line temp. High side pressure: 335psi = 104 saturation temp. 83.1 high side line temp. Temp at the vent in rooms: 56.1F + or minus. Temp from supply side: 55.2F. Recharge kit with gauge and hose $29.95. Now with a new shut-off valve standard ¼ ” SAE. R410A 2 lb. FREE SHIPPING NATIONWIDE (CONTINENTAL US) 100% VIRGIN FACTORY SEALED. GUARANTEED PRODUCT QUALITY. Ability Refrigerant stocks a large store of R22, R410A, MO99, 407C, 404A and R134A. VIEW SAFETY DATA SHEET. 95%.characteristics similar to R-22. Freon™ 410A is a non-ozone depleting blend of two HFC refrigerants. It exhibits higher pressures and refrigeration capacity than R-22. The …Apr 14, 2019 · R410A Pressure Enthalpy Chart. Scroll down to download a PDF copy of the pressure enthalpy chart for both Metric and Imperial Units. These charts were provided courtesy of Danfoss, using their FREE CoolSelector 2 software. erties of R-410A are very similar to those for R-22 as well as most of today’s HFC refrigerants. The major difference is the higher pressure. 2. Follow general safety guide-lines. Refrigerants can be used safe-ly when recommended safety and handling practices are followed. Pressure, frostbite, overexposure to vapors and deliberate inhalation are

The maximum recommended temperature is often around 150 to 160 degrees Fahrenheit (65.6 to 71.1°C) for the condenser coil. What is normal subcooling for 410A? Normal subcooling for R-410A systems can range from 10 to 20 degrees Fahrenheit (5.6 to 11.1°C) depending on the specific system design and conditions.If you want to make the products you sell more appealing to your customers, check out the countertop display refrigerators for your store or bar. * Required Field Your Name: * Your...The Internet of Things—a world where most working objects are online in some fashion—promises to change everyday life and boost the economy. But who knew it could make it cheaper t...Who invented the refrigerator is explained in this article from HowStuffWorks. Find out who invented the refrigerator. Advertisement You might hate dragging your groceries home and...Refrigerant R-410A Pressure Temperature Chart – R410A is an HFC and is commonly used in residential and light commercial HVAC equipment for air conditioners and heat pump systems. It widely replaces HCFC R-22 which was mandated by the Montreal Protocol to be phased out of production and use by 2020.Lower GWP (465) compared to R32 and R410a; Close operating pressures and temperature with R410-a, making transition easier Other approved R410a replacements. In addition to these two refrigerants, the EPA’s SNAP Rule 32 identifies four more A2L refrigerants as approved alternatives to R410-A: R452B; R454A; R454C; …Freon ™ 410A Refrigerant (R-410A) Replacement for R-13B1: Properties and Operating Characteristics ... pressure refrigerants can be used with Freon™ 410A. However, mixing refrigerants should be avoided. Freon™ 410A Rereran Table 1. General Properties of Freon™ 410A and R-13B1This is where our friend R-410A came into play. New machines from 2010 and onwards were banned from using R-22. Instead, they were outfitted with R-410A. If you would like to read more about R-410A refrigerant please have a look at our Puron fact sheet. R-410A PT Chart. Let’s take a look at our pressure table for R-410A Puron.The purpose of refrigerator coils is to dissipate heat, not suck up electricity—or cash—out of your wallet. But that's what happens if you don't clean off those bad boys once in a ...What are some reasons to buy a freezerless refrigerator? Find out 5 reasons to buy a freezerless refrigerator in this article. Advertisement Chances are pretty good that the fridge...As an HVAC technician or someone interested in air conditioning systems, understanding the key factors that impact 410A refrigerant pressures is crucial. The proper functioning of ...Whether you're looking for a commercial open-air refrigerator or an under-counter freezer, our list of the best commercial refrigerators certainly has something for you. * Required...

This is a highly rated tank that can handle the high pressures of 410A refrigerant. Recovery Machine – A recovery machine for 410A must be approved for Class V refrigerants including R-407C, R-404A, R-507, and R-410A per AHRI 740-98. The recovery machine should have the following features: over sized condenser, over sized fan, crankcase ...

The change over of refrigerant from R22 to R410 actually started way back in 1992. Due to some environmental regulations that were put in place, many different countries decided to phase out the use of R-22 and replace it with R410a. R410a is more efficient and environmentally friendly than R-22. Differences Between R-22 and R410a R-22Mar 19, 2019 · This is where our friend R-410A came into play. New machines from 2010 and onwards were banned from using R-22. Instead, they were outfitted with R-410A. If you would like to read more about R-410A refrigerant please have a look at our Puron fact sheet. R-410A PT Chart. Let’s take a look at our pressure table for R-410A Puron. Refrigerant Pressure Temperature Chart - PT Chart for R-410A, R-134A, and R-22. These are currently the three most widely used refrigerants on the market today for HVAC applications in residential and commercial use. R-22 refrigerant is the king and used widely in the residential and commercial markets followed by R-134A which is used in ...This is where our friend R-410A came into play. New machines from 2010 and onwards were banned from using R-22. Instead, they were outfitted with R-410A. If you would like to read more about R-410A refrigerant please have a look at our Puron fact sheet. R-410A PT Chart. Let’s take a look at our pressure table for R-410A Puron.Refrigerant Pressure - Temperature Chart. Pressure values are displayed for R-22, R-410a, R-407c, R-134a and R-404a refrigerants. Items Displayed in Red shows pressure in inches of Mercury. Items Displayed in Black shows pressure in pounds per inch gauge. Data points are reproduced based on available information.r-410a pressure temperature chart psig f° psig f° psig f° psig f° psig f° psig f° 12 -37.7 114 37.8 216 74.3 318 100.2 420 120.7 522 137.6 14 -34.7 116 38.7 218 74.9 320 100.7 422 121 524 137.9 16 -32.0 118 39.5 220 75.5 322 101.1 424 121.4 526 138.3The recommended pressure for a home refrigerator using R134A refrigerant is between 2 psig and 150 psig. Readings that are higher or lower indicate an overcharged system. Although ...R-410A _____ SDS: R-410A Page 3 of 8 Current Issue Date: January 04, 2021 UNUSUAL FIRE AND EXPLOSION HAZARDS: R-410A is not flammable at ambient temperatures and atmospheric pressure. However, this material will become combustible when mixed with air under pressure and exposed to strong ignition sources.Mar 19, 2019 ... R-410A PT Chart ; –37.7, -38.7, 12, 82.7 ; –34.7, -37.0, 14, 96.5.

Muscle burns fat results.

Great lakes spring challenge 2023.

Cooling index merupakan tingkat pendinginan freon. Flammability merupakan tingkat kemudahan terbakar freonnya. Dari tabel tekanan freon R32, R22, dan R410a, bisa disimpulkan beberapa hal, yakni sebagai berikut. Freon R32 jauh lebih ramah lingkungan dibanding freon R410a karena tingkat GWP-nya lebih rendah dibandingkan …Aug 5, 2023 ... FKmechofficial R410a | R410a Suction & Discharge pressure | R410a Rotary compressor pressure r410a suction pressure, r410a discharge ...R410a is part of the hydrofluorocarbon (HFC) class of refrigerants and is composed of an equal amount of R125 and R32. Its chemical formula is CH₂F₂ + CHF₂CF₃ and its cylinders are colored rose. R410a was discovered by Honeywell and was granted a patent in 1991. It is the most used refrigerant in home and commercial ACs in the US, …Temp. Temp. Temp. Temp. Temp. Temp. Temp. Temp. ( F) Liquid Vapor ( C) ( F) Liquid Vapor ( C) ( F) Liquid Vapor ( C) ( F) Liquid Vapor ( C)-49 5.5 5.4 -45.0 1 49.7 49.5 -17.2 …Jan 3, 2024 · An R-410A Pressure-Temperature (PT) chart is a tool used in HVAC systems to determine the corresponding saturation temperature of the R-410A refrigerant at different pressures. This chart is essential for HVAC technicians as it helps in diagnosing and maintaining air conditioning systems. R410A is a blend of two hydrofluorocarbon (HFC) refrigerants: R32 and R125. These two components work together to create a refrigerant with excellent thermodynamic properties. R32 provides high energy efficiency, while R125 contributes to the stability and heat transfer performance of R410A. When it comes to the chemical composition of R410A ...R-410A systems operate at higher pressures than standard R-22 systems. Do not use R-22 service equipment or components on R-410A equipment. Ensure service equipment is rated for R-410A.! WARNING Refrigeration systems contain refrigerant under pressure. Extreme caution should be observed when handling refrigerants. Wear safety glasses and gloves ...According to the R-22 PT chart, this is equal to about 54°F. With the thermometer, we measured the saturated R-22 temperature of 45°F. Here is how we can calculate the R-22 superheat in this system: Superheat (R-22) = 54°F – 45°F = 9°F. The superheat calculator also gives us 9°F superheat for R-22 refrigerant.With the regulatory phase-out of R22, the HVAC sought out an alternative refrigerant that prioritizes environmental friendliness and energy efficiency. One such substitute that has gained widespread acceptance is R410A, a hydrofluorocarbon (HFC) blend. Unlike R22, R410A does not contribute to ozone depletion and has a lower GWP. ….

Recently a new refrigerant, R-410A, has been formu-lated and currently is being used in the HVAC/R industry. It was developed primarily because the pro-duction of R-22 is scheduled to stop soon. The phaseout schedule for R-22, as mandated by the Environmental Protection Agency (EPA), will be dis-cussed in more detail at the end of …High-Pressure Appliance (prior to March 12, 2004, referred to by the EPA as higher-pressure appliance) An appliance that uses a refrigerant with a liquid phase saturation pressure between 170 psia and 355 psia at 104°F. This definition includes but is not limited to appliances using R-410A, R-22, R-401B, R-402A/B, R-404A, R-In 2014, the original European F-gas Regulation [11] was replaced by EU Regulation No 517/2014 of the European Parliament and the Council [12] to limit the amount of fluorinated gases sold in Europe from 2015 onwards, and to reduce their sale by one-fifth until 2030 [4].R-410A is among the most affected refrigerants in this new regulation …High Pressure: R-410A works best at a pressure of at least 400 pounds per square inch (psi). If this pressure is exceeded, the compressor will wear out quickly. This means that if you have an old home with poor insulation and weak ductwork, you will need to install a booster fan as well as a larger condenser coil.You can make ads in the Engineering ToolBox more useful to you! The relation between temperatures and boiling pressuress for. R-717 : Ammonia. R-134a : Tetrafluoroethane. R-22 : Hydrochlorofluorocarbon. R-507 : R-290 : Propane. R-744 : CO 2. are indicated in the diagrams below:However, a common guideline for R-410A systems is to aim for a superheat value in the range of 10 to 20 degrees Fahrenheit (°F) or approximately 5.6 to 11.1 ...4 Using Table 2, select the column which is closest to the measured vapor pressure. 5 Scroll down the column to find your calculated superheat. 6 Read the required vapor line temperature at the intersection. (°F) If the measured vapor line temperature does not agree with the required vapor line. 7 temperature, add refrigerant to lower ...An R-22 Replacement for New ACs and Heat Pumps. Freon™ 410A (R-410A) refrigerant offers higher cooling capacity and significantly higher pressure than R-22 for use in … Thermodynamic Properties of DuPontŽ Suva ® 410A Refrigerant English (I/P) Units New tables of the thermodynamic properties of DuPont™ Suva® 410A refrigerant [ASHRAE designation: R-410A (50/50)], have been developed and are presented here. These tables are based on extensive experimental measure-ments. Equations have been developed, based ... Refrigerant 410a pressure, Forane 410A Pressure Temperature Chart Forane 410A, R-410A, Pressure Temperature Chart, PT Chart, HVAC, refrigeration, air conditioning, refrigerant gas, Typical Low Side Pressure Range for R410A in the field: 115-120 psi. Typical High Side Pressure Range for R410A in the field: 410-420 psi. By 2025, high Global Warming Potential (GWP) refrigerants with a GWP of over 750, will be banned together with the systems using that gas. R410A has a GWP > 2,000., R22 can absorb and release less heat which can lead to compressor burnout over time. On the other hand, R-410A can handle more heat allowing the compressor to run cooler. The compressors used in new AC units are built to withstand greater pressure that is caused by R-410A refrigerant., If your refrigerator broke down, would you be stuck with the repair costs? Learn what’s covered under your fridge’s warranty and how a home warranty can help. Expert Advice On Impr..., R-410A! AVAILABLE IN SIZES "REFRIGERANT Type Size R-410A Cylinder 25 lb. 100 lb. 850 lb. 1,450 lb. R-410A Composition: (R-32 / 125) • (50 / 50 wt%) Application: Air conditioning equipment and heat pumps. Only for newly manufactured equipment, NOT for retrofitting R-22 Performance: Pressures are 60% higher than R-22, therefore should be used only, Oct 13, 2017 · What is R-410A? R-410A is an HFC refrigerant that is a blend of the HFC R-32 and the HFC R-125. This refrigerant was designed to be a safe, non-toxic, non-flammable, and reliable alternative to the HCFC R-22. It was invented in 1991 but did not begin to see real popularity until the 2000’s. , 2 Way Water Regulating Valves. Control pressure in refrigerant systems with these 2-way, water-regulating valves. Direct-acting valves open on pressure increase to regulate the flow of water or glycol to water-cooled condenser refrigeration systems. Pressure-balanced, modulating valves provide precise control of head pressure on open or closed ..., R410A is a Hydrofluorocarbon (HFC ) Systems using R410A refrigerant run at a pressure of approximately 1.6 times that of similar systems using R22 and the energy efficiency is comparable. The R410A refrigerant is a 50:50 mixture of R32 and R125. Page 8 R410A in detail R410A is a Zeotropic blend of two refrigerants R32 50% R125 50% The phase ..., Apr 14, 2024 · Using the formulas provided: Condensing Temperature = 35°C + 10°C = 45°C. Evaporation Temperature = 27°C – 20°C = 7°C. These calculations serve as rough estimates. To ascertain the operational pressures of the compressor: For R22 refrigerant: High pressure is approximately 1.75 MPa. Low pressure is approximately 0.6 MPa. , Temperature and pressure chart for refrigerants R22, R410A, R12, R134A, R401A, R409A, R502, R404A, R507A, R408A and R402A. Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications! , If your refrigerator broke down, would you be stuck with the repair costs? Learn what’s covered under your fridge’s warranty and how a home warranty can help. Expert Advice On Impr..., Experiments are carried out here to measure the evaporation heat transfer coefficient hr and associated frictional pressure drop ΔPf in a vertical plate heat exchanger for refrigerant R-410A. The heat exchanger consists of two vertical counterflow channels which are formed by three plates whose surface corrugations have a sine shape and a …, R410A Pressure Enthalpy Chart. Download a PDF copy of the pressure enthalpy chart for both Metric and Imperial Units. By. Paul Evans - Apr 14, 2019. 2. ... pressure enthalpy chart; refrigerant properties; Facebook. Twitter. Pinterest. WhatsApp. Previous article R407F Pressure Enthalpy Chart. Next article R417A Pressure Enthalpy …, Whether you're looking for a commercial open-air refrigerator or an under-counter freezer, our list of the best commercial refrigerators certainly has something for you. * Required..., What is R-410A? R-410A is an HFC refrigerant that is a blend of the HFC R-32 and the HFC R-125. This refrigerant was designed to be a safe, non-toxic, non-flammable, and reliable alternative to the HCFC R-22. It was invented in 1991 but did not begin to see real popularity until the 2000’s., R‐410A. Version 2.5 Revision Date 04/18/2022 Document 10005001 . Page 1 of 8 SECTION 1 ‐ CHEMICAL PRODUCT AND COMPANY IDENTIFICATION . PRODUCT NAME : R‐410A OTHER NAME : Difluoromethane, Pentafluoroethane PRODUCT USE : Refrigerant gas, for professional use only Restrictions : Do not use product for anything …, VRV/VRF REFRIGERANT PIPING 232301 - 1 SECTION 232301 – VRV/VRF REFRIGERANT PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes refrigerant piping used for VRV/VRF air-conditioning applications. 1.2 PERFORMANCE REQUIREMENTS A. Line Test Pressure for Refrigerant R-410A: 1., Monitor refrigerant pressure with analog gauges when servicing air conditioning systems. All manifolds have double O-ring piston valves. Manifolds with sight glass allow you to view liquid levels.. Replacement gauges are sold separately.. Optional gauge cover sets (sold separately) include one blue and one red gauge cover. They are not for use with the …, Freon™ 410A provides comparable performance to R-13B1 in most very low temperature, (VLT) applications. R-13B1 is an ozone-depleting refrigerant, and production has ceased as mandated by the Montreal Protocol and other legislation. Freon™ 410A offers similar performance to R-13B1 in existing systems, however, some equipment modifications, R-410A requires specialized tools to handle the higher pressure as well. R-410A does NOT contribute to O-Zone depletion. R-410A does have a higher global warming potential. (2088 times the effect of carbon dioxide.) R-410A is a mixed refrigerant. It is blended with HFC-32 and HFC-125, although they perform as a single refrigerant., Oct 13, 2017 · What is R-410A? R-410A is an HFC refrigerant that is a blend of the HFC R-32 and the HFC R-125. This refrigerant was designed to be a safe, non-toxic, non-flammable, and reliable alternative to the HCFC R-22. It was invented in 1991 but did not begin to see real popularity until the 2000’s. , system charge chart - refrigerant 410a pressure at suction service port (psig) connect pressure gauges to suction and liquid ports on unit. measure air temperature to outdoor coil. place an "x" on the appropriate chart where the suction and liquid pressures cross. if "x" is below ambient temperature line, add charge and repeat step 3., Solstice® 454B (R-454B) has properties very similar to R-410A. With accommodations for the mild flammability of R-454B, it is a good match for equipment previously designed for R-410A. Applications for Solstice® 454B (R-454B) include the commercial systems. It is also important to understand (only for new equipment and subject to the ..., Saturation Pressure-Temperature Data for R410A (psig)*. Temp (°F) Pressure. Temp (°C), pressure of about 250 psi at an outdoor temperature of 95°F. With R-410A, the same unit will operate under the same conditions with a suction pressure of 118 psi and a discharge pressure of 400 psi, as shown in Figure 1 on the next page. (Note that in most cases, equipment designed for R-22 cannot use R-410A because of this difference in operating, A 410a PT chart is a tool that shows the saturation pressure of 410a refrigerant at various temperatures. Saturation pressure is the pressure at which the refrigerant changes phase from liquid to vapor, or from vapor to liquid, depending on the temperature. A 410a PT chart can be used to answer questions such as:, Freon™ 407C and Freon™ 410A Refrigerant Descriptions Freon™ 407C is a non-ozone depleting blend of three hydrofluorocarbon (HFC) refrigerants. It exhibits performance characteristics similar to R-22. Freon™ 410A is a non-ozone depleting blend of two HFC refrigerants. It exhibits higher pressures and refrigeration capacity than R-22. , 1000 600 400 200 Enthalpy (BTU/lb) 140 410A Refrigerant (R-410A) P-H Diagram (ENG Units) Enthalpy (BTU/lb), Temp. Temp. Temp. Temp. Temp. Temp. Temp. Temp. ( F) Liquid Vapor ( C) ( F) Liquid Vapor ( C) ( F) Liquid Vapor ( C) ( F) Liquid Vapor ( C)-49 5.5 5.4 -45.0 1 49.7 49.5 -17.2 51 145.8 145.2 10.6 101 323.1 322.1 38.3-48 6.0 5.9 -44.4 2 51.1 50.8 -16.7 52 148.4 147.9 11.1 102 327.7 326.7 38.9, Both the R454B and R410A are safe to use. They are both non-toxic and stable inside any refrigeration system. Also, when handled by an expert, you can expect both to be safe to use. However, R454B seems to be mildly flammable if exposed to atmospheric pressure. It has a A2L ASHRAE classification., Freon ™ 410A Refrigerant (R-410A) Replacement for R-13B1: Properties and Operating Characteristics ... pressure refrigerants can be used with Freon™ 410A. However, mixing refrigerants should be avoided. Freon™ 410A Rereran Table 1. General Properties of Freon™ 410A and R-13B1, If you want to make the products you sell more appealing to your customers, check out the countertop display refrigerators for your store or bar. * Required Field Your Name: * Your..., R410A Pressure Temperature Chart (In Fahrenheit) Printable PDF Temp er atu r e (° F ): R410A P r essu r e (p si g ):-60 ° F 0. 9 psi g-55 ° F 1. 8 psi g-50 ° F 4. 3 psi g-45 ° F 7. 0 psi g-40 ° F 10. 1 psi g-35 ° F 13. 5 psi g-30 ° F 17. 2 psi g-25 ° F 21. 4 psi g-20 ° F 25. 9 psi g-18 ° F 27. 8 psi g