Chlorinator off high salt amps

High Salt/Amps The “Chlorinator Off High Salt” warning comes on when the current exceeds 8 amps regardless of the salt level. This can be caused by high salt but also by high water temperatures. If it says high salt, the amps were above 8.0. If the volts are more than 32 at any point, the circuit board is probably damaged.

Chlorinator off high salt amps. Step 8: To bring the pool chlorinator level down, you will have to push the minus button you can find on the Hayward Aqua Logic or Pro Logic motherboard. If you want to bring the pool chlorinator level up, you will have to press the plus button instead. You will locate the plus and minus buttons in the middle of the control panel.

Mineral salts are substances extracted from bodies of water and below the Earth’s surface. Some examples of mineral salts include sodium, chlorine, calcium, phosphate, magnesium, s...

This light is a red warning indicator and will only illuminate when the salt level in the swimming pool is higher than 4500 parts per million. If this light is on, decrease the output by turning the chlorine control, (2 in fig.2), anticlockwise until the high salt (red light) goes off and the 10 chlorine output LEDs are on (1 in fig 2). If thisI was still getting the "High Salt/Amps" message. I installed the new display and corrected the day and time. All other settings were still correct, including the Cell configuration (T-15). I checked the Volts and Amps and Salt levels. The readings were the same for both + and - polarities: 40.62V, 10.04A, and 1900PPM.2 timer periods/day 25gms/hr 4,100 to 8000 96,000 50,000 8 amps Salt Chlorination is the accepted standard for pool and spa sanitation in Australia and AstralPool’s range of salt chlorinators is recognized by the pool and spa professional as one of the most reliable and sophisticated salt chlorinator systems available. R SHEET DWG. NO ...Low and High Salt Alarms can be observed when the salt in parts per million is outside of the expected range in a Body Of Water. Salt Chlorination takes place while the Salt Level is between 2400 and 3800 ppm . A Low Salt Alarm is generated when the Salt ppm is between 2400 and 2700 ppm for Standard. For Low Salt Monitoring it is between 800 ...Step 5. Check Salt Level - Most salt chlorine generators will shut down the cell's salt levels are outside the prescribed range. For example, the Pentair Intellchlor’s operational salinity range is 3000 - 4200 ppm (ideal 3400 ppm.). If the salt level is outside of this range, the CHECK SALT light will flash, and the cell will shut down until ...Poolrite SureChlor S3500 RP 35g Pool Chlorinator (Retrofits AKS, Surechlor, Enduro & Endurochlor Chlorinators) 94. … chlorinator is a robust, long-lasting, efficient chlorinator that will perform day in and day out with no issues. Poolrite is a very familiar brand for many pool & spa owners in Australia.

Chlorinator OFF, High Salt/Amps (cont.) The message ‘Chlorinator Off – High Salt/Amps’ indicates that the ProLogic has detected an amperage draw, from the turbo …Switch power to the Pool Lab salt chlorinator off at the power outlet and wait at least 10 seconds. If there is a Pool Lab ASP (Auto Sampling Photometer) connected, unplug it …Human Salt Consumption - Human salt consumption should be regulated because too much salt can cause problems, such as hypertension. Learn more about human salt consumption. Adverti...Again, test the water for an accurate salt reading, and add more salt according to your owner's manual recommendation of 2,700–3,400 ppm (parts per million), or the ideal of 3,200 ppm for Hayward AquaRite salt systems. 7. "High Salt" Light On. Test the salt levels in your pool, and make sure the salinity level is under 3,400 ppm.I have a high salt amps message. chlorinator off when I start chlorinator the values that come up are,40.58V, 1O.08a. 83F and 1900 ppm. I also replaced the cell yesterday. read moreVolts & Amps Guide. Please note: • Warmer water and higher salt will decrease voltage. • Colder water, lower salt, scaled, or depleted cell will increase voltage. • It is better to run on a lower power level and higher output percentage, than a higher power level and lower output percentage. Please note: • Warmer water and higher salt ...Salt chlorinator use an electrolytic cell to sanitise your pool. In this article, we will examine the common faults of pool chlorinators and how to fix them.

Signs that indicate that your system is not working include: Low chlorine levels in the pool water. No Flow indication on the flow monitor. Corroded plates. Indicator lights signaling cell damage. When the saltwater chlorinator fails, it cannot produce enough chlorine to meet the swimming pool needs.What is you actual salt level, not from the units readout but actual. If the salt is low (1900) the unit will be working harder to try and produce the chlorine which can harm the power unit. Water is more conductive with 3500 salt so less power Volts and amps required. A guy quite recently published a schematic on here and that showed 22.8v I have the "Chlorinator off High salt/amps" message. Contractor's Assistant: I'll do all I can to help. How long have you been dealing with this? I replaced the CG a couple of months ago and currently it is reporting 4600 PPM on the salt. just this past week, and the pool turned green on me wed-today I shocked at lunch to get the green cleared up, but bigger concern is the CG not generating Low and High Salt Alarms can be observed when the salt in parts per million is outside of the expected range in a Body Of Water. Salt Chlorination takes place while the Salt Level is between 2400 and 3800 ppm . A Low Salt Alarm is generated when the Salt ppm is between 2400 and 2700 ppm for Standard. For Low Salt Monitoring it is between 800 ...I am having the same problem but it isn't immediate. I get a good reading as follows: -27.23v -5.11a 96 F 3200 PPM It works fine for a minute then gives...chlorine production by measuring the amps drawn by the chlorinator cell in each polarity. 1. Switch power to the Pool Lab salt chlorinator off at the power outlet and wait at least 10 seconds. 2. If there is a Pool Lab ASP (Auto Sampling Photometer) connected, unplug it from the port at the bottom of the power pack.

12275 price club plaza fairfax va 22030.

Retest your water the following day and further adjust the dial or turn off the machine, if necessary. [1] If you turn off the machine, be sure to test the water 2-3 times per day, and turn the machine back on when the chlorine drops below 3.0 ppm. 2. Remove all chlorine additives from the pool, if applicable.This light is a red warning indicator and will only illuminate when the salt level in the swimming pool is higher than 4500 parts per million. If this light is on, decrease the output by turning the chlorine control, (2 in fig.2), anticlockwise until the high salt (red light) goes off and the 10 chlorine output LEDs are on (1 in fig 2). If thisSaltmate saltwater electrolytic cells are constructed with premium grade high production material and are designed with high flow rate parallel plates. All Saltmate saltwater chlorinators can be installed onto new or existing pools without the need to change any other filtration equipment and are also compatible with mineral salt blends. Models.I have a high salt amps message. chlorinator off when I start chlorinator the values that come up are,40.58V, 1O.08a. 83F and 1900 ppm. I also replaced the cell yesterday. read more

Low and High Salt Alarms can be observed when the salt in parts per million is outside of the expected range in a Body Of Water. Salt Chlorination takes place while the Salt Level is between 2400 and 3800 ppm . A Low Salt Alarm is generated when the Salt ppm is between 2400 and 2700 ppm for Standard. For Low Salt Monitoring it is between 800 ... Apr 17, 2012 · Split from the Aqua-logic salt too high-cholrinator off high salt/amps topic. Bama I'm having the same exact problem, but did not find any weak or burnt... However, when I tested it with the salt strip again, it read 2800ppm. This salt level would be fine for the regular salt chlorinator but I found nothing online about a low salt chlorinator. Does anyone know if 2800ppm is too high for a low salt chlorinator system? I also plan on just taking a sample of water for professional testing tomorrow.Check Salt High Salt Inspect Cell Maximum Current (Amps) before shutdown T-Cell 3: 4.15 T-Cell 5: 6.40 T Cell 9: T Cell 15. 9.50 10.00 If salt level is above the range, partially drain pool and/or spa and refill with fresh water to achieve a salt level of 3200ppm. ( RULE of THUMB: Each inch of water drained will reduce the salt level IOOppm.) O ...Step 5. Check Salt Level - Most salt chlorine generators will shut down the cell's salt levels are outside the prescribed range. For example, the Pentair Intellchlor’s operational salinity range is 3000 - 4200 ppm (ideal 3400 ppm.). If the salt level is outside of this range, the CHECK SALT light will flash, and the cell will shut down until ... How To Tell If Salt Cell Needs Replacing | Best Price Pool Equipment. Skip to content. Fast Delivery Available! 211 Stirling Highway, Claremont, WA 6010. 0412 561 620. Email Nicole. About Nicole. Nicole’s Advice. Warranty. Set TurboCell® Type & Reset Average Salt 10-11 Adjust Chlorine Output & Clean TurboCell 12-15 Troubleshooting: Pg. 16-38 1. Check Salt & Inspect Cell: flashing or ON 17-20 2. High Salt: LED ON 21-25 3. No Flow: LED flashing or ON 26-30 4. Display ONLY, Lights ONLY, or Neither 31-36 5. LCD: Displaying HOT or COLD _ 37-38Hayward Aqua plus says “chlorinator off high salt amps”. This is after I had to resolder the circuit board for - Answered by a verified Pool and Spa Expert We use cookies to give you the best possible experience on our website.If you have high blood pressure or heart, liver, or kidney problems, your health care provider may suggest you lower your sodium intake. Look for these words on labels: low-sodium,...Chlorinator Off - Test Salt Level Message Maximum Current (Amps) before shutdown T-Cell 3: 5.50 T Cell 9: 10.00 T-Cell 5: 6.75 T Cell 15: 10.00 Before operation, the Aqua Rite must be configured for the chlorinator cell that will …The T-Cell-15 is the most popular Hayward TurboCell size. It’s designed for pools up to 40,000 gallons — but I’m getting ahead of myself. First I have to lay the groundwork so this all makes sense. The days of using liquid or tablet chlorine in your swimming pool is a thing of the past — well, at least it should be.

How To Tell If Salt Cell Needs Replacing | Best Price Pool Equipment. Skip to content. Fast Delivery Available! 211 Stirling Highway, Claremont, WA 6010. 0412 561 620. Email Nicole. About Nicole. Nicole’s Advice. Warranty.

The aquapod is saying high salt/high amps, chlorinator off. The diagnostics is showing 2700 ppm salt (not high) and a salt test strip showed something …I have a T-Cell-15, My pool control panel says "Pool Chlorinator 30%" "Chlorinator Off - High Salt Amps" Screen Says "Main Software Revision 2.85" "Display Software Revision 3.11" What do you suggest so that I can get my pool back to salt. Aqua Plus Control Panel.....last year it was saying "no cell power" but doesn't anymore.In this video, our Tech Brady from the Nicholasville store explains some information about Hayward's Aqua Rite Salt Cell. This information is for the general...We recommend that pool owners choose a cell size that is at least 1.5 – 2.0 times their pool size. This means the cell would not need to work as hard to keep up with your chlorine needs. Save money with the CP-15 Replacement Cell for Aqua Rite T Cell 15. Question: My salt system reads Check System HI salt/amps and is not making chlorine.Sep 15, 2019 · The shock is great but that doesn't address the salt cell and the shock will wear off. Make sure the ph is in the 7.2 to about 7.8 range and your Calcium which is the big reason you have to clean the cell less than 450 ppm. Mar 17, 2012. #11. Re: Salt Reading too high & Chlorinator replacement question. Its a Hayward/Goldline installed by Blue Haven Pool Company in April 2007. UPDATE: So, I took ya'lls advice and I went to our regular pool store and Leslie's to compare the testing results on a fresh sample of water yesterday.ProLogic: How It Works. • All ProLogic systems are salt chlorination ready and can control 4-16 high voltage relays, 3-4 valve actuators and 1-2 heaters. • These systems can manage: Hayward Variable Speed Pumps, ColorLogic Lighting, Sense & Dispense, AquaConnect Homenet, as well as a wide variety of remotes.You only need to enjoy the spa-like feel of the clear, soft, and clean water. While this is a good option for a salt water chlorinator and rightfully in the top 50% of the 24 salt pool systems we tested, it is on the pricier side and has been known to have issues with durability past 1 year of use. 11. Intex Krystal.Nov 12, 2021 ... ... Pools, Inc.•530K views · 12:08. Go to channel · Chlorinator Off No Cell Power - DIY Repair. FiveAble•90K views · 1:54. Go to channel &midd...

All about eyes forsyth il.

Pro1 t701 thermostat manual.

I recently used chlorine bleach to clean the siding on my house, and I was amazed at how well it worked! What is bleach? How does it remove stains? Is the chlorine in bleach the sa...Step 5. Check Salt Level - Most salt chlorine generators will shut down the cell's salt levels are outside the prescribed range. For example, the Pentair Intellchlor’s operational salinity range is 3000 - 4200 ppm (ideal 3400 ppm.). If the salt level is outside of this range, the CHECK SALT light will flash, and the cell will shut down until ...I have an aqua rite salt chlorine system with a T-15 turbo cell. My average salt reading is 2100ppg and the instant reading is 210ppg. The check salt and inspect cell lights are constantly on (not bli … read moreI do now show in diagnostics initial voltage on start up 40v 10.2 amp 2200 ppm after replacing k1 while before just 0 0 and then shut down no power (the default screen shows salt 3600 ppm) It tries and shows error high salt/high amp few times then stops with no cell powerAdd to cart. AquaJoy Unique G25 chlorinator 20 amp. $1,721.50 $1,399.95. PRODUCT DESCRIPTION. SPECIFICATIONS. CUSTOMER REVIEWS. PRODUCT DESCRIPTION. The AquaJoy Unique G25 chlorinator is designed to provide an advanced and reliable solution for maintaining your pool's water quality. Its innovative features, durability, and …RUN. Watts Run kWh. 1000. For example, to run a WATERMAID® WM40 chlorinator for 10 hours per day during off peak hours, where the off peak rate of electricity is 8.8 cents/kWh, the electricity cost will be: = 300 (Watts) ÷ 1000 x 10 (Hours) x 8.8 (kWh) = 26.4 c / day. Off Peak Hours = 10pm - 7am, 7 days. 17.Low voltage' Next message is 'Chlorinator off. Instant salt' I noticed this - Answered by a verified Pool and Spa Expert. We use cookies to give you the best possible experience on our website. ... I have a Hayward goldline pro logic with a message that reads chlorinator off high salt amps. The values are at 40.58v, 10.08a.Volts & Amps Guide. Please note: • Warmer water and higher salt will decrease voltage. • Colder water, lower salt, scaled, or depleted cell will increase voltage. • It is better to run on a lower power level and higher output percentage, than a higher power level and lower output percentage. Please note: • Warmer water and higher salt ...The Insnrg Vi Premium Chlorinator has one of the most premium price tags for chlorinators on the market today. The small size of this machine, the Vi25, will cost you about $4,800, while the Vi40 will cost approximately $5,500. These high price tags are due to the technology and automation-oriented components of the machine, which is unique ...JustAnswer-Q&A. 8.12K subscribers. Subscribed. 0. 1.2K views 2 years ago. From https://www.justanswer.com/ythi JustAnswer Customer from San Antonio, TX: I have the "Chlorinator off High...Oct 6, 2020 · In fact, most of the time, they’re easier. BUT they are a little different. 1. Inspect regularly for scale. One of the biggest problems with salt chlorine generators is that they tend to produce a lot of scaling (or calcium deposits). To keep this at a manageable level, check your generator every 2-3 months. ….

Adjusting Chlorine Output Pg. 6 High Salt LED ON Pg. 7 No Flow LED flashing or ON Pg. 8 No LED’s/LCD display Pg. 9-12 Low/High Cell temperature Pg. 13 Cell cleaning instructions Pg. 14-16 Troubleshooting flow charts Pg. 17-21 Salt Chart Pg. 22 Software Revision Compatibility Chart Pg. 23 Important Information- Chlorine output and salt Pg. 24 ...I am having the same problem but it isn't immediate. I get a good reading as follows: -27.23v -5.11a 96 F 3200 PPM It works fine for a minute then gives...The Vapure salt and mineral chlorinator is Australian made and 'simply reliable'. Available in 15g, 25g, 35g, 45g and 55g. Features include: - Salt operation: 3,000-3,500PPM with built in self-regulator for high salt. - Low Salt models (25G/35G): 1,000 - 1,500 PPM with build in self-regulator for high salt.Jul 11, 2021 · From https://www.justanswer.com/ythiJustAnswer Customer: I have a high salt amps message.JustAnswer Customer: chlorinator off when I start chlorinator the va... Low and High Salt Alarms can be observed when the salt in parts per million is outside of the expected range in a Body Of Water. Salt Chlorination takes place while the Salt Level is between 2400 and 3800 ppm . A Low Salt Alarm is generated when the Salt ppm is between 2400 and 2700 ppm for Standard. For Low Salt Monitoring it is between 800 ...Check the Timer settings. The chlorinator turns on then turns off. The circuit breaker may be tripping. This can be due to excessively high salt levels. There may be a short across the Cell plates. Check the Cell …If all zeros or if Chlorinator Off Percentage Met, press ~+ key. IF, after a short countdown delay, the display does not revert to zeros, refer to step 3. NOTE: The main circulation pump MUST be ON and the chlorinator AND flow switch MUST have flow to successfully complete this process. 2 Above is an example of the updated instant salt reading ...A salt water chlorinated pool requires much less attention than a chlorine pool. A salt water pool provides a more comfortable swimming environment. Easy to Program Hydrochlor TS features an easy to use analogue timer. ... Just move the tappets to either the on or off position to program the chlorinator. Battery Back Up A battery backup is ...Mar 17, 2012. #11. Re: Salt Reading too high & Chlorinator replacement question. Its a Hayward/Goldline installed by Blue Haven Pool Company in April 2007. UPDATE: So, I took ya'lls advice and I went to our regular pool store and Leslie's to compare the testing results on a fresh sample of water yesterday.Technical Specifications. Produces 25 grams of chlorine gas per hour. Ideal salt level 3000ppm with water at 25°C. Suits outdoor pools up to 90,000 litres. Suits indoor pools up to 150,000 litres. Cell has 50mm unions (reducers not included) 5 … Chlorinator off high salt amps, Hayward Aqua plus says “chlorinator off high salt amps”. This is after I had to resolder the circuit board for another issue that was keeping the chlorinator off. …, AutoPilot Pool Pilot Tech Support & Troubleshooting Request. SaltPoolGuys.com is the leading authorized dealer of AutoPilot Pool Pilot salt systems. We stock a full selection of replacement parts & cells with shipping nationwide. As a service to AutoPilot Pool Pilot salt chlorine generator owners we offer free technical support to help with ..., Salt Chlorinator incorporates a very smart algorithm ... EQ35 Chlorinator 12805 520135 520136 35 gm/hr 130,000 80,000 120,000 250,000 8.5 amps 10 amps EQ45 Chlorinator 12806 520135 520136 45 gm/hr 170,000 105,000 120,000 250,000 8.5 ... ** Tropical climate water temperatures are warmer and require higher chlorine output to combat algae and ..., The Viron Saltwater Chlorinator continually generates chlorine at the level you require allowing you to set and forget. With easy to use touch pad, intelligent self-cleaning of the cell, pool & spa dosing control and a filter backwash timer, you count on the Viron Saltwater Chlorinator to keep your pool looking crystal clear., ‘Chlorinator Off High Temperature’ means the current chlorinator cycle has been interrupted due to a cell temperature reading of more than 140 ° F. Page 14 , The Hydrochlor Mineral Chlorinator includes an energy saving, intelligent power pack that makes it easy to keep your pool sanitised and healthy to swim in. Chlorination. The main function of the Hydrochlor Mineral Chlorinator is to produce chlorine to sanitise the pool water. Pool water, which contains dissolved Mineral Crystals / pool salt ..., I just replaced my T-cell 86 Turbo cell with a newly T-cell 54. When the system starting in race I get this message, "Chlorinator Off Elevated Salt/Amps." Then late for the messages I get, "Check System High Salt/Amps." I checked the instant salt reading and it is 8147, which EGO know is way too great. I..., Get free real-time information on CHF/SALT quotes including CHF/SALT live chart. Indices Commodities Currencies Stocks, Technical Specifications. Produces 25 grams of chlorine gas per hour. Ideal salt level 3000ppm with water at 25°C. Suits outdoor pools up to 90,000 litres. Suits indoor pools up to 150,000 litres. Cell has 50mm unions (reducers not included) 5 …, Low temperature: If the water is too cold, below 70 ° -65 ° F (21 ° -18 ° C), your chlorinator will not be able to produce chlorine even if your salt level is perfect. Salt Chlorinator Flashing High or Low Salt: Make sure to test your salt levels and adjust it to around 3400ppm. if the salt level is off, the salt chlorinator will not work., Again, test the water for an accurate salt reading, and add more salt according to your owner's manual recommendation of 2,700–3,400 ppm (parts per million), or the ideal of 3,200 ppm for Hayward AquaRite salt systems. 7. "High Salt" Light On. Test the salt levels in your pool, and make sure the salinity level is under 3,400 ppm., Salt is a common substance that is found in a wide variety of foods. Learn about salt, the properties of salt and the manufacturing of salt. Advertisement Salt is salt, right? When..., for the correct period and turns off the electrolytic cell, preventing excessive build ... constructed to withstand high temperature and UV radiation in the harsh Australian environment. ... V35 Viron Salt Chlorinator 10816 35gm/h 130,000 80,000 8 amps 10 amps V45 Viron Salt Chlorinator 10817 45gm/h 170,000 105,000 8 amps 10 amps, AutoPilot Pool Pilot Tech Support & Troubleshooting Request. SaltPoolGuys.com is the leading authorized dealer of AutoPilot Pool Pilot salt systems. We stock a full selection of replacement parts & cells with shipping nationwide. As a service to AutoPilot Pool Pilot salt chlorine generator owners we offer free technical support to help with ..., Sep 15, 2019 · The shock is great but that doesn't address the salt cell and the shock will wear off. Make sure the ph is in the 7.2 to about 7.8 range and your Calcium which is the big reason you have to clean the cell less than 450 ppm. , Fix your Hayward Salt Chlorinator system instead of replacing it. When the generating light shuts off after a few seconds when you turn your system on, a $3 ..., The Vapure salt and mineral chlorinator is Australian made and 'simply reliable'. Available in 15g, 25g, 35g, 45g and 55g. Features include: - Salt operation: 3,000-3,500PPM with built in self-regulator for high salt. - Low Salt models (25G/35G): 1,000 - 1,500 PPM with build in self-regulator for high salt., My salt was high in my pool and got a high salt amps chlorinator off reading. I drained some water, salt was tested by Leslie's and salt is at 3200ppm. Tested salt cell (brand new) and is working properly. I am still getting the "chlorinator off high salt/amps" reading and it's telling me that the salt is at 1900ppm., When you have 0 ppm chlorine showing, in all likelihood it’s a salt cell problem (i.e. the cell is dirty, damaged or needs to be replaced). Check to see that the chlorinator is actually set to something above zero and wasn’t accidentally turned off i.e. 50% is a common setting. Check to see that everything is plugged in properly and look ..., Step 5. Check Salt Level - Most salt chlorine generators will shut down the cell's salt levels are outside the prescribed range. For example, the Pentair Intellchlor’s operational salinity range is 3000 - 4200 ppm (ideal 3400 ppm.). If the salt level is outside of this range, the CHECK SALT light will flash, and the cell will shut down until ..., Home - Trouble Free Pool | Trouble Free Pool, Salt prevents bad bacteria from thriving—so how can it "go bad"? Salt is an incredibly common ingredient that most of us take for granted. It’s a simple, inorganic (meaning “not ca..., Human Salt Consumption - Human salt consumption should be regulated because too much salt can cause problems, such as hypertension. Learn more about human salt consumption. Adverti..., Mar 18, 2011 ... Hayward Aqua and Pro Logic Salt Cell Output Adjustment ... Chlorinator Off No Cell Power - DIY Repair ... Put Salt on Your Electrical Soldering iron ..., Once your water has been tested, if the reading is too high, reduce the levels of salt in your pool to bring your levels back to the recommended 3200 ppm. Verify if the control is set to the correct turbo cell. Verify cell amperage to ensure it is not above the maximum limit for your model. Check below for the maximum currents AMPS before the ..., From https://www.justanswer.com/ythiJustAnswer Customer: I have a high salt amps message.JustAnswer Customer: chlorinator off when I start chlorinator the va..., Home - Trouble Free Pool | Trouble Free Pool, What is you actual salt level, not from the units readout but actual. If the salt is low (1900) the unit will be working harder to try and produce the chlorine which can harm the power unit. Water is more conductive with 3500 salt so less power Volts and amps required. A guy quite recently published a schematic on here and that showed 22.8v, 3. High Salt Light – Fig. 2: This light is a red warning indicator and will only illuminate when the salt level in the swimming pool is higher than 4500 parts per million. If this light is on, decrease the output by turning the chlorine control, (2 in fig.2), clockwise until the high salt (red light) goes off, Main Takeaways. A salt chlorine generator uses salt and a process called electrolysis to sanitize your pool. The two main parts of a salt chlorine generator are the salt cell and the control board. Some of my top tips for maintaining your salt chlorine generator include: maintaining salt levels between 2,700 and 3,400 ppm, cleaning the ..., AutoPilot Pool Pilot Tech Support & Troubleshooting Request. SaltPoolGuys.com is the leading authorized dealer of AutoPilot Pool Pilot salt systems. We stock a full selection of replacement parts & cells with shipping nationwide. As a service to AutoPilot Pool Pilot salt chlorine generator owners we offer free technical support to help with ..., I have a high salt amps message. chlorinator off when I start chlorinator the values that come up are,40.58V, 1O.08a. 83F and 1900 ppm. I also replaced the cell yesterday. read more, If the amps on either reading show zero (0), then you should replace your Main PC Board (GLX-PCB-RITE). If the amps show a reading that isn’t within range, then you should replace your Turbo Cell. High Salt LED ON. The High Salt LED stays on when: The cell amperage is above the maximum limit. You have too much salt in your pool.